KatInterview

Low-Power Wrist Pulse Tracker: Sensing and Duty-Cycling Design

System DesignModel answer
HardModel answerSystem Designembedded-systemssignal-processingpower-management

Last updated

Design a wrist-worn pulse-tracking subsystem that stays under a 5 mW budget, updates within 2 seconds, and stays accurate during arm motion and poor sensor contact.

Design a Wrist-Worn Pulse Tracking Subsystem

You are designing the pulse-tracking part of a compact fitness watch. It has to deliver trustworthy readings while running on a tiny battery and fitting into a very small enclosure.

Behavior required

  • While the wearer is at rest, the watch tracks beats per minute (BPM) continuously.
  • During intense workouts, it switches to a higher-effort mode that samples more aggressively.

Limits you must meet

  • Power: the sensing subsystem draws under 5 mW on average.
  • Responsiveness: a real change in pulse rate shows on the display within 2 seconds.
  • Accuracy: at least 95% of readings are correct, even with motion artifacts such as arm swing while running.

What to cover in your answer

  1. Hardware: which sensors you would include (for example optical pulse sensing, an accelerometer, and anything else) and why.
  2. Processing pipeline: how raw samples are handled, and how the work is divided between low-level sensor firmware and the main application processor (AP).
  3. Power management: how you duty-cycle the system to save energy without losing important data.
  4. Failure handling: what happens when the signal drops out because of loose skin contact or stray ambient light.

Be explicit about assumptions, give rough power numbers, and discuss the trade-offs behind your choices.

Hints

Hint 1

Begin with the power budget: the main processor costs on the order of 100 mW when awake, so most of the design is about keeping it asleep and letting a tiny always-on microcontroller do the real-time work.

Hint 2

Treat the accelerometer as a noise reference as well as an activity detector. Think about how an adaptive filter and spectral peak tracking can remove motion components that sit in the same frequency band as the pulse.

Hint 3

Define operating states (off-wrist, rest, active, workout) with hysteresis, and attach a signal-quality score to every output so that bad data degrades gracefully instead of showing a wrong number.